- Research
- Open access
- Published:
The effect of electronic monitoring combined with weekly feedback and reminders on adherence to inhaled corticosteroids in infants and younger children with asthma: a randomized controlled trial
Allergy, Asthma & Clinical Immunology volume 16, Article number: 68 (2020)
Abstract
Background
Adherence to asthma treatment among children is usually poor. We sought to explore whether electronic adherence monitoring combined with weekly feedback regarding adherence along with a reminder to use inhaled corticosteroids (ICS) would lead to improved compliance with ICS in infants and younger children with asthma.
Methods
96 recruited children (aged 6 months to 3 years) with mild or moderate persistent asthma who were on regular inhaled corticosteroids were randomly allocated to receive electronic monitoring combined with instant messaging software (IMS)-based weekly feedback regarding adherence along with a reminder to keep taking the ICS (intervention group) and to receive electronic monitoring only (control group).
Results
The mean device-monitored adherence was significantly higher in the intervention group (80%) than in the control group (45.9%), with a difference of 34.0% (95% confidence interval [CI], 26.8–41.3%; P < 0.001). No difference in the mean caregiver-reported adherence between the interventional group (89.7%) and the control group (92.7%) was observed (P = 0.452).
Conclusions
Electronic monitoring combined with IMS-based weekly feedback regarding adherence along with a reminder to keep taking the ICS significantly improved the treatment compliance of infants and younger children with asthma. Caregiver-reported adherence is an unreliable monitoring indicator.
Trial registration ClinicalTrials.gov, NCT03277664. Registered 11 September 2017—Retrospectively registered, https://clinicaltrials.gov/ct2/results?cond=&term=NCT03277664
Background
Daily inhaled corticosteroids (ICS) is associated with improved asthma control, but poor adherence to medication regimens is associated with poor disease control [1], decreased lung function [2], increased need for oral steroids [3, 4], severe attacks of wheeze [5], and increased readmission rate [6]. Adherence of 49–71% of asthma medication has been observed in children and adolescents by objective measurements [7, 8].In infants and young children, adherence to prescribed asthma medication is extremely variable [9, 10] and adherence levels decrease over time [9]: mean adherence in young children (aged 15 months to 5 years) with asthma was 71% in an observational study lasting 2 months [11], but it was only 57% in another study lasting 9 months [12]. Therefore, it’s very necessary to find out effective strategies to improve poor treatment adherence.
Accurately evaluating treatment adherence in children with asthma is the first step to assess the effectiveness of a therapeutic schedule. There are a number of subjective and objective measures for healthcare professionals to assess treatment adherence. However, adherence to ICS monitored by subjective tools such as caregiver report is frequently overestimated compared with objective measures [13]. As an objective method, electronic monitoring devices (EMDs) are regarded as the gold standard in adherence monitoring for their ability to provide detailed information about patterns of treatment use [14].
Effective interventions improving treatment adherence in children with asthma with solid evidence are scarce [8]. Appropriate feedback on treatment adherence by EMD-based reminders [14, 15], sharing adherence data with the child, parent, and physician during the consultation [16], asthma education [17], and real-time medication monitoring with tailored short message service reminders [18] might effectively enhance the treatment adherence among asthma patients.
In this study, we aimed to investigate the effect of electronic monitoring combined with instant messaging software (IMS)-based weekly feedback regarding adherence plus reminder to take medication on adherence to ICS in infants and younger children with asthma.
Methods
This was a multicenter, single-blind, parallel-group randomized controlled clinical trial, with an allocation ratio of 1:1(Fig. 1). Written consent was obtained from the parents of all participants. The study was conducted in accordance with the current Good Clinical Practice, and the protocol was approved by an Independent Ethics Committee or Institutional Review Board for each center. The protocol was registered in ClinicalTrials.gov, number NCT03277664.
Participants and setting
Children aged 6 months to 3 years who attended Shanghai Children’s Medical Center and 14 community hospitals in Shanghai, China, with doctor-diagnosed asthma were screened for eligibility. Asthma was diagnosed according to Global Initiative for Asthma criteria [19] and to the guideline for the diagnosis and optimal management of asthma in children(2016) [20]. The inclusion criteria were as follows: (1) patients having mild or moderate persistent asthma and (2) patients taking regular ICS with no change in their medication in the last month. At present, budesonide is the only ICS approved by the U.S. Food and Drug Administration for children with asthma aged less than 4 years [20, 21]. The monitoring device available for this trial was compatible only with budesonide nebulizer. Therefore, all participates were prescribed budesonide, and all of them had a nebulizer before recruitment. Participants who had severe persistent asthma or another respiratory disease (eg, a chronic lung disease other than asthma, respiratory health impacted by cardiac conditions, or another medical co-morbidity) or did not live in Shanghai were excluded.
Interventions
Before randomization, all participants had the same chips attached to their regular nebulizers. The SmartTrack Device (Shanghai Sonmol Internet Technology Co. Ltd, Shanghai, CHN; Fig. 2), which is attached to the surface of the nebulizer, can monitor the daily use of the nebulizer. The device records the date, time, and number of actuations used. The usage data were saved in the smart device and automatically transferred to the central server via Bluetooth. All caregivers had their nebulizer technique checked by a qualified asthma nurse and received a brief asthma education session after randomization, emphasizing the importance of taking ICS regularly. All participants were reviewed in their routine asthma clinics 3-monthly, and all treatment decisions were made by the clinical team according to asthma guidelines [19, 20]. Data were collected and adherence rates were calculated weekly.
Intervention group
All the device-monitored adherence data from the previous week were downloaded from the database and calculated by a qualified asthma nurse. Through free IMS (WeChat; Tencent, Shenzhen, CHN) available on smart phone, the nurse offered feedback to the caregivers weekly according to the adherence rate and reminded them to keep taking the ICS. Caregivers were asked monthly “Has our child inhaled the medicine according to the doctor’s instructions?” and “How about the frequency?” by telephone.
Control group
All the device-monitored adherence data were downloaded from the background database and calculated weekly. However, feedback and reminders were not given to the caregivers. Caregiver reported medication compliance was assessed monthly, in the same way as the intervention group.
Primary outcome
The primary outcome of the study was change in the adherence rate monitored by the electronic device for 6 consecutive months. This adherence rate was calculated as the number of device recorded times /number of total times prescribed × 100%.
Secondary outcomes
The secondary outcomes for the study were the caregiver-reported adherence rate and the difference between device-monitored and caregiver-reported adherence rates for 6 consecutive months. The caregiver-reported adherence rate was recorded on a monthly basis. It was offered by the caregivers of patients through answering the questions “Has our child inhaled the medicine according to the doctor’s instructions” and “How about the frequency”. The device-monitored and caregiver-reported adherence rates were compared monthly.
Sample size
Tests for two proportions in a repeated measures design were used for sample size calculation by PASS 12 Power Analysis and Sample Size Software (NCSS, LLC. Kaysville, Utah, USA). Group sample sizes of 42 and 42 achieve 80.8% power to detect an odds ratio of 2.679 [22] in a design with 6 repeated measurements having a Compound Symmetry covariance structure when the proportion from group 2 is 0.519 [22], the correlation between observations on the same subject is 0.5, and the alpha level is 0.05. The aim was to recruit 96 participants to allow for a 15% attrition rate.
Randomization and blinding
Patients were randomly assigned 1:1 to the intervention group or the control group by a researcher using a computer-based minimization procedure who was not otherwise involved in the study. The caregivers of participants and follow-up nurse were not blinded owing to the nature of the intervention. However, the doctors and statisticians were blinded. Adherence data were not available to clinicians in both the groups.
Statistical analysis
Data were presented as means and standard deviation for continuous variables and frequencies and percentages for categorical variables. In the bivariate analysis, significance was determined by the t test for continuous variables and by the Chi square test for categorical variables. General linear models with repeated measures were used to compare adherence levels across time between the groups. A two-tailed P value <.05 was taken as statistically significant. Analyses were performed using IBM SPSS Statistics version 25 (IBM, Armonk, NY, USA) software.
Results
Patients
From September 2016 to January 2017, 139 asthma patients aged 6 months to 3 years were assessed for eligibility. After exclusions, 96 participants were enrolled and randomly assigned (46 to the intervention group and 50 to the control group). Baseline characteristics were similar in both groups (Table 1). Six-month follow-up was completed for 40 (87.0%) in the intervention group and 46 (92.0%) in the control group; overall, 86 children (89.6%) in total completed the study protocol. No adverse events related to the intervention were identified or reported during the study.
Primary outcome
Figure 3 shows impact of intervention (weekly check in and feedback regarding adherence) over time. Compared with the control group (45.9%), the mean device-monitored adherence was significantly higher in the intervention group (80.0%), with a difference of 34.0% (95% confidence interval [CI], 26.8–41.3%; P < 0.001). The mean device-monitored adherence difference (95% CI) at 3 and 6 months for the intervention group, compared with the control group was 35.2% (17.3–53.1%) and 47.3% (29.7–64.9%), respectively.
Secondary outcome
We noted no difference in the mean caregiver-reported adherence rates between the intervention group (89.7%) and the control group (92.7%) (P = 0.452). The consistency between the caregiver-reported adherence and the device-monitored adherence was poor (Table 2). The mean caregiver-reported adherence was significantly higher in both groups compared with the mean device-monitored adherence, with a difference of 9.8% (95% CI, 4.0–15.6%; P = 0.001) and 46.8% (95% CI, 40.8–52.8%; P < 0.001) for the intervention group and the control group, respectively.
Discussion
To our knowledge, this is the first and largest randomized controlled study powered to detect the effect of electronic monitoring combined with IMS-based weekly feedback and reminders on adherence to ICS in infants and younger children with asthma.
Significantly higher device-monitored adherence observed in the intervention group than in the control group could be caused both by the weekly feedback regarding adherence and by the weekly reminders to keep taking the ICS, since they might effectively address the problem of ‘forgetting’, which has been reported by parents as one of the principal barriers to adherence for young children [23], and improve awareness of non-adherence. However, which part of the intervention is most likely to have caused the study effect is unclear for that we did not set up subgroups to compare the effect of the two on adherence, respectively. It is likely that the weekly reminders to keep taking the ICS in this study played a major role in improved adherence, since using feedback regarding adherence alone in other studies has been observed no improvement in adherence to ICS therapy [17, 24], while using reminders alone was associated with increased adherence to asthma treatment [18, 25].
Similar reminder strategies, such as biweekly telephone education (overall adherence rate: 74.3%) [22], EMD-based audiovisual reminder (median percentage adherence: 84%) [14], and sharing adherence data with the child, parent, and physician during the consultation (mean adherence: 79%) [16] could also significantly increase adherence of asthma treatment. Compared with these methods, ours could achieve comparable results (mean adherence: 80%) and could be considered to be a good alternative for improving adherence to asthma treatment among children. In addition, all of those strategies were mainly implemented among children over 6 years old and may not be suitable for infants and younger children while ours could fill this gap well.
In usual outpatient follow-up process without appropriate intervention, adherence in the control group declined dramatically over the study. This phenomenon may be caused by vary reasons such as “Erratic non-adherence” (forgetfulness or a busy, unpredictable lifestyle), “Unwitting non-adherence” (failure to appreciate the specifics of treatment or the need for adherence), and “Intelligent non-adherence” (a purposeful choice to reduce or discontinue ICS use for many reasons) [26]. However, IMS-based weekly feedback regarding adherence along with a reminder to keep taking the ICS could significantly improve this situation. In the intervention group, adherence fell slightly over time and appeared to be stable after 4 months (over 70%).
Compared with objective measurements, subjective measurements tend to overestimate the level of adherence [7]. In our study, the mean caregiver-reported adherence was also significantly higher in both groups compared with the mean device-monitored adherence. Monthly, we asked caregivers to describe the ICS inhalation frequency prescribed to be taken and to report how many times their child missed taking the ICS in this month. Without appropriate prompts, this kind of caregiver-reported adherence might not be sensitive enough to detect non-adherence. Poor consistency between the caregiver-reported adherence and the device-monitored adherence (Table 2) makes the former not to be a reliable tool for assessing adherence.
One limitation of our study was the lack of investigation on improvements in asthma outcomes among our groups. In fact, similar studies indicate that electronic adherence monitoring with feedback and reminders is likely to be of significant benefit in the improvement of asthma outcomes in children [14, 15]. High levels of adherence to ICS in young children with asthma have been shown to be associated with better asthma control [27, 28] and a reduction in exacerbations [5]. However, in order to make the conclusion more convincing in infants and younger children with asthma, it is recommended that the following related studies should include the evaluation of asthma control levels and exacerbations. The fact that the study was done using nebulized budesonide was another limitation, because this way of administering drugs is much more time-consuming and cumbersome than the metered dose inhaler/spacer combination which is the preferred delivery system for young children with asthma in most of the world. However, each of the delivery devices can be equally efficacious in patients using the correct technique for inhalation [29] and similar devices exist for pressurized metered-dose inhalers. Therefore, our intervention (weekly reminders with information about adherence) can be generalized to other devices/delivery methods.
Conclusions
These data indicate that electronic monitoring combined with IMS-based weekly feedback regarding adherence along with a reminder to keep taking the ICS significantly improved adherence to ICS in infants and younger children with asthma. Caregiver-reported adherence is not a reliable tool for assessing adherence.
Availability of data and materials
Raw data for this study were collected on excel sheet using a data pro forma. The data are available from the corresponding author upon reasonable request.
Abbreviations
- CI:
-
Confidence interval
- EMD:
-
Electronic monitoring device
- ICS:
-
Inhaled corticosteroids
- IMS:
-
Instant messaging software
References
Jentzsch NS, Camargos P, Sarinho ES, Bousquet J. Adherence rate to beclomethasone dipropionate and the level of asthma control. Respir Med. 2012;106(3):338–43.
Duncan CL, Hogan MB, Tien KJ, Graves MM, Chorney JM, Zettler MD, Koven L, Wilson NW, Dinakar C, Portnoy J. Efficacy of a parent-youth teamwork intervention to promote adherence in pediatric asthma. J Pediatr Psychol. 2013;38(6):617–28.
Bender B, Zhang L. Negative affect, medication adherence, and asthma control in children. J Allergy Clin Immunol. 2008;122(3):490–5.
Milgrom H, Bender B, Ackerson L, Bowry P, Smith B, Rand C. Noncompliance and treatment failure in children with asthma. J Allergy Clin Immunol. 1996;98(6 Pt 1):1051–7.
Williams LK, Peterson EL, Wells K, Ahmedani BK, Kumar R, Burchard EG, Chowdhry VK, Favro D, Lanfear DE, Pladevall M. Quantifying the proportion of severe asthma exacerbations attributable to inhaled corticosteroid nonadherence. J Allergy Clin Immunol. 2011;128(6):1185–1191.e1182.
Suissa S, Ernst P, Kezouh A. Regular use of inhaled corticosteroids and the long term prevention of hospitalisation for asthma. Thorax. 2002;57(10):880–4.
Desager K, Vermeulen F, Bodart E. Adherence to asthma treatment in childhood and adolescence—a narrative literature review. Acta Clin Belg. 2018;73(5):348–55.
Klok T, Kaptein AA, Brand PLP. Non-adherence in children with asthma reviewed: the need for improvement of asthma care and medical education. Pediatr Allergy Immunol. 2015;26(3):197–205.
Schultz A, Sly PD, Zhang G, Venter A, Devadason SG, le Souef PN. Usefulness of parental response to questions about adherence to prescribed inhaled corticosteroids in young children. Arch Dis Child. 2012;97(12):1092–6.
Iqbal S, Ritson S, Prince I, Denyer J, Everard ML. Drug delivery and adherence in young children. Pediatr Pulmonol. 2004;37(4):311–7.
Gibson NA, Ferguson AE, Aitchison TC, Paton JY. Compliance with inhaled asthma medication in preschool children. Thorax. 1995;50(12):1274–9.
Armstrong ML, Duncan CL, Stokes JO, Pereira D. Association of caregiver health beliefs and parenting stress with medication adherence in preschoolers with asthma. J Asthma. 2014;51(4):366–72.
Bender B, Wamboldt FS, O’Connor SL, Rand C, Szefler S, Milgrom H, Wamboldt MZ. Measurement of children’s asthma medication adherence by self report, mother report, canister weight, and Doser CT. Ann Allergy Asthma Immunol. 2000;85(5):416–21.
Chan AHY, Stewart AW, Harrison J, Camargo CA, Black PN, Mitchell EA. The effect of an electronic monitoring device with audiovisual reminder function on adherence to inhaled corticosteroids and school attendance in children with asthma: a randomised controlled trial. Lancet Respir Med. 2015;3(3):210–9.
Morton RW, Elphick HE, Rigby AS, Daw WJ, King DA, Smith LJ, Everard ML. STAAR: a randomised controlled trial of electronic adherence monitoring with reminder alarms and feedback to improve clinical outcomes for children with asthma. Thorax. 2017;72(4):347–54.
Burgess SW, Sly PD, Devadason SG. Providing feedback on adherence increases use of preventive medication by asthmatic children. J Asthma. 2010;47(2):198–201.
Otsuki M, Eakin MN, Rand CS, Butz AM, Hsu VD, Zuckerman IH, Ogborn J, Bilderback A, Riekert KA. Adherence feedback to improve asthma outcomes among inner-city children: a randomized trial. Pediatrics. 2009;124(6):1513–21.
Vasbinder EC, Goossens LM, Rutten-van Molken MP, de Winter BC, van Dijk L, Vulto AG, Blankman EI, Dahhan N, Veenstra-van Schie MT, Versteegh FG, et al. e-Monitoring of Asthma Therapy to Improve Compliance in children (e-MATIC): a randomised controlled trial. Eur Respir J. 2016;48(3):758–67.
Global Initiative for Asthma. Global Strategy for Asthma Management and Prevention, 2016. www.ginasthma.org.
Guideline for the diagnosis and optimal management of asthma in children. Chin J Pediatr. 2016;54(3):167–81.
Shen K, Deng L, Li Y, Li C, Liu E, Chen Q, Chen Y, Chen Z, Chen A. Haozhang: expert consensus on the application of glucocorticoid aerosol inhalation therapy in pediatrics (revised version in 2014). J Clin Pediatr. 2014;32(6):504–11.
Chatkin JM, Blanco DC, Scaglia N, Wagner MB, Fritscher CC. Impact of a low-cost and simple intervention in enhancing treatment adherence in a Brazilian asthma sample. J Asthma. 2006;43(4):263–6.
Burgess SW, Sly PD, Morawska A, Devadason SG. Assessing adherence and factors associated with adherence in young children with asthma. Respirology. 2008;13(4):559–63.
Williams LK, Peterson EL, Wells K, Campbell J, Wang M, Chowdhry VK, Walsh M, Enberg R, Lanfear DE, Pladevall M. A cluster-randomized trial to provide clinicians inhaled corticosteroid adherence information for their patients with asthma. J Allergy Clin Immunol. 2010;126(2):225–231.e224.
Strandbygaard U, Thomsen SF, Backer V. A daily SMS reminder increases adherence to asthma treatment: a three-month follow-up study. Respir Med. 2010;104(2):166–71.
Organization WH: Adherence to long-term therapies. Evidence for action 2003. http://www.who.int/chp/knowledge/publications/adherence˙report/en/. Accessed 13 Dec 2016.
Lasmar L, Camargos P, Champs NS, Fonseca MT, Fontes MJ, Ibiapina C, Alvim C, Moura JA. Adherence rate to inhaled corticosteroids and their impact on asthma control. Allergy. 2009;64(5):784–9.
Klok T, Kaptein AA, Duiverman EJ, Brand PL. It’s the adherence, stupid (that determines asthma control in preschool children)! Eur Respir J. 2014;43(3):783–91.
Dolovich MB, Ahrens RC, Hess DR, Anderson P, Dhand R, Rau JL, Smaldone GC, Guyatt G. Device selection and outcomes of aerosol therapy: evidence-based guidelines: American College of Chest Physicians/American College of Asthma, Allergy, and Immunology. Chest. 2005;127(1):335–71.
Acknowledgements
This study was supported by Project Hope, China Pediatric Asthma Prevention and Management Program. It also was supported by AstraZeneca Investments Limited, China. The authors acknowledge all investigators and patients who contributed to the study.
Funding
This study was funded by AstraZeneca China. It was also funded by the Shanghai Shen Kang Hospital Development Center – Appropriate Technology Joint Development and Popularization Project “The promotion of nebulization technology based on the standardized management of asthma in family and community for children” (No. SHDC12016216) and the Shanghai Shen Kang Hospital Development Center Projects for the Prevention and Control of Chronic Diseases (No. SHDC12015306). It was also funded by the key projects of the Shanghai Science and Technology Department of Medicine (No. 16411955100), Scientific research project of Shanghai Pudong New Area Health Committee (No. PW2017E-1), the Discipline Construction of Nursing Plateau (No. hlgy16030kyg8), the Study on Schema Design for Enhancing the Compliance of Inhaled Corticosteroids in Asthmatic Children Based on Information Platform (No. jyh1519), and Scientific research projects of Shanghai Science and Technology Commission (No. 19441909000).
Author information
Authors and Affiliations
Contributions
JC, JX and LZ substantially contributed to the conception of the study. They interpreted the results for this study, drafted, wrote and revised the article, and approved the final manuscript as submitted. JZ made substantial contributions to designing and conducting the study and was responsible for collecting data. YY and FZ conceived of the study, participated in its design and coordination, helped to review the manuscript. All authors read and approved the final manuscript.
Corresponding authors
Ethics declarations
Ethics approval and consent to participate
This study was conducted with the approval of the Ethics Committee of Shanghai Children’s Medical Center. An informed consent was obtained from the legal guardian/s.
Consent for publication
All authors have read and approved the content, and they agree to submit it for consideration for publication in the journal.
Competing interests
The authors declare that they have no competing interests.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Chen, J., Xu, J., Zhao, L. et al. The effect of electronic monitoring combined with weekly feedback and reminders on adherence to inhaled corticosteroids in infants and younger children with asthma: a randomized controlled trial. Allergy Asthma Clin Immunol 16, 68 (2020). https://doi.org/10.1186/s13223-020-00466-6
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s13223-020-00466-6