A single centre retrospective study of systemic reactions to subcutaneous immunotherapy

Abstract

Background

Subcutaneous immunotherapy (SCIT) is the standard approach for treating patients with sensitizations to aeroallergens. However, immunotherapy can trigger severe systemic reactions if delivered inappropriately or to high risk patients. We sought to characterize and quantify SCIT systemic reactions requiring epinephrine administration during a 6-year period in a Canadian setting following the recommendations for components and dosages published in the 2010 Canadian Society of Allergy and Clinical Immunology (CSACI) Immunotherapy Manual.

Methods

A single centre retrospective chart review was performed for all patients with systemic reactions to subcutaneous immunotherapy requiring intramuscular epinephrine injection between January 2011 and October 2017. Each systemic reaction requiring epinephrine was reviewed for baseline patient characteristics, details of the reaction, and reaction severity. Research ethics approval was obtained through McMaster University.

Results

28 of 380 patients experienced a systemic reaction requiring epinephrine administration, with an incidence rate of 1 per 1,047 injection visits (0.095%). 26 of the 28 reactions occurred within the mandatory 30-minute observation period post allergen immunotherapy. Of the 28 patients that experienced a systemic reaction to SCIT, 11 patients had asthma and 5 patients had a history of possible food allergy. All of the systemic reactions occurred during injections from vial number 4, and five patients reacted to their first shot of a re-ordered extract. 10 of the 28 patients required more than one intramuscular injection of epinephrine, and 20 of 28 patients were transferred to the hospital by ambulance.

Conclusions

This is the first Canadian study to review patients with systemic reactions to subcutaneous immunotherapy. Several best practice methods were employed throughout the study to optimize subcutaneous delivery of immunotherapy extract, and our recorded per injection incidence rate for systemic reactions was comparable or below the rate published in similar studies. The recommendations in the CSACI Immunotherapy Manual provide an approach to standardizing prescriptions for SCIT to maximize immunotherapy efficacy and reduce the risk of systemic reactions, though similar studies in larger multicenter settings are needed to confirm these observations. These observations provide important objective information to clinicians about the potential risks for systemic reactions in patients considering SCIT.

Background

Subcutaneous immunotherapy (SCIT) is the standard approach for treating patients with sensitizations to aeroallergens if medical therapy is ineffective or not preferred [1], with a strong evidence base supporting its use [1, 2]. Systemic reactions represent the major adverse effect of immunotherapy. Risk factors for systemic reactions include symptomatic asthma, injections from new vials, injections during symptomatic seasons, dosing errors, history of previous systemic reactions and the use of beta-blockers [2]. These reactions can be severe, and in rare cases, fatal [1].

Multiple studies have tried to characterize the underlying risks and quantify the incidence of systemic reactions and deaths due to SCIT. Several surveys have reported that the fatality rate is estimated to be approximately 1 in 2.5 million injections. [3,4,5] Although these fatal reactions are rare, the generally accepted incidence of systemic reactions per injection is between 0.1% and 0.3% [6,7,8] Furthermore, retrospective and prospective studies of inhalant immunotherapy following conventional schedules have been reported from the United States [7,8,9] Turkey [10, 11], Israel [12], Portugal [13], Italy [14, 15], and Spain [16]. However, Canadian data has not yet been published.

To standardize the delivery of SCIT, recommendations for immunotherapy extract components and dosages were published in the 2010 Canadian Society of Allergy and Clinical Immunology (CSACI) Immunotherapy Manual. Appropriate allergen dosing, mixing and build up schedules are provided in order to improve the efficacy and safety of SCIT. The objectives of this study were to characterize and quantify SCIT systemic reactions requiring epinephrine administration in a Canadian setting from 2011 to 2017 following the publication of the 2010 CSACI Immunotherapy Manual [17].

Methods

A retrospective chart review was performed for all patients with systemic reactions to aeroallergen subcutaneous immunotherapy requiring intramuscular epinephrine injection at a single referral clinic of an Allergist in Kitchener, Ontario, Canada. The data was collected for reactions to the subcutaneous injection of glycerinated extracts (Hollister Stier, Spokane, Washington, USA) requiring epinephrine that occurred between January 2011 and October 2017, following the publication and adoption of the recommendations within the 2010 CSACI Immunotherapy Manual. All patients with a clinical history of asthma were first assessed with spirometry prior to initiation of SCIT to ensure an FEV1 greater than 80%. Asthma symptoms were well controlled in all patients prior to each injection. Any first injections of new extract were administered with a volume reduction of at least 50%. The total number of injections administered at the clinic during the study period was also documented.

Each systemic reaction requiring epinephrine was reviewed for baseline patient characteristics (age, sex, past medical history including the presence of asthma and food allergies, use of beta-blockers, angiotensin converting enzyme inhibitors or angiotensin receptor blockers, and positive skin tests prior to starting SCIT), and the details of the reaction (severity, date and season in which the reaction occurred, the dose of immunotherapy and whether the extract was a new reorder, the allergens in the extract, time course, specific symptoms, blood pressure, treatments including the epinephrine dose and subsequent doses, and transfer to the hospital).

Reaction severity was determined by the 2010 World Allergy Organization (WAO) subcutaneous immunotherapy systemic reaction grading system (Table 1) [6].

Table 1 2010 World Allergy Organization (WAO) subcutaneous immunotherapy systemic reaction grading system

Research ethics approval was obtained through McMaster University in Hamilton, Ontario, Canada (Project number: 4213-C).

Results

Between January 2011 and October 2017, 380 patients received aeroallergen SCIT with a total of 29,334 injections administered. Of these 380 patients, 28 patients (7.4%) experienced systemic reactions requiring epinephrine administration (Table 2). The incidence rate of reactions requiring epinephrine was 1 per 1,047 injection visits (0.095%).

Table 2 Patient demographic and clinical characteristics

In this population of patients that experienced a systemic reaction to SCIT, no patients were on beta-blockers, angiotensin converting enzyme inhibitors or angiotensin receptor blockers. However, there was a male predominance in the 28 patients that experienced a systemic reaction, with 19 (68.9%) males and 9 (32.1%) females. No age predilection could be identified, with an age range between 8 to 60 years (median 34 years; four patients under the age of 18). The number of positive skin tests to environmental allergens prior to starting SCIT ranged from 3 to 11.

Of the 28 patients that experienced a systemic reaction to SCIT, 11 patients had asthma (39.3%) and 5 patients (17.9%) had a history of possible food allergy. Of these five, 4 had confirmed food allergy, with allergies to crustaceans, peanut, tree nuts and carrots.

There was no statistically significant seasonal predominance for the timing of systemic reactions; however, there was an increase in the number of reactions during the winter months. Reactions occurred during all seasons with 5 reactions (17.9%) in the spring, 5 in the summer (17.9%), 8 in the autumn (28.6%), and 10 in the winter (35.7%).

The injected extracts contained different combinations of dust mite, grass, ragweed, trees, mold, cat, and dog allergens. The number of allergen extracts administered on one visit with one or two injections ranged from 2 to 7, with different tree species considered a single aggregate allergen. All systemic reactions occurred during injections from vial number 4 (most concentrated extract), with injection volumes ranging from 0.05 ml to 0.5 ml. Five (17.9%) patients reacted to their first injection of a re-ordered (i.e. new vial of) extract.

Out of the 28 reactions identified, 26 reactions (92.9%) occurred within the mandatory 30-min observation period post allergen immunotherapy as recommended in the 2010 CSACI Immunotherapy Manual. Only 2 reactions (7.1%) occurred outside of the mandatory observation period, with one patient experiencing a reaction shortly after departing the observation environment, and another reaction occurring approximately 90 min after the injection was given.

There was an even distribution of the severity of reactions. Eight patients (28.6%) experienced grade 1 reactions, 9 patients (32.1%) experienced grade 2 reactions, 8 patients (28.6%) experienced grade 3 reactions, and 3 patients (10.7%) experienced grade 4 reactions (Table 3) according to the WAO grading scale [6]. No grade 5 reactions occurred.

Table 3 Summary of patients with grade 4 reactions

Of the 28 patients receiving epinephrine, 10 patients (35.7%) received more than one intramuscular injection of epinephrine, and 1 patient (3.6%) received a dose of epinephrine subcutaneously (0.1 ml of 1:1000 epinephrine) at the SCIT injection site in addition to the initial dose of intramuscular epinephrine. In total, 20 (71.4%) patients were transferred to the hospital by ambulance.

Discussion

This is the first Canadian study to review patients with systemic reactions to aeroallergen subcutaneous immunotherapy. The 2010 CSACI Immunotherapy Manual [17] provided recommendations for SCIT administration, including standardized dosages (when available) and immunotherapy extract components based on published data. In our study, we focused on documenting the patient characteristics and reaction details following the adoption of these guidelines in an attempt to elicit common predisposing risk factors for systemic reactions while on subcutaneous immunotherapy. Our recorded incidence rate for systemic reactions was approximately 0.095% per injection, comparable or below the rate published in similar studies (0.1% to 0.3%) [7,8,9, 18]. Our low incidence rate may simply have been skewed by the inclusion criteria used in our retrospective review (administration of intramuscular epinephrine). However, we felt this requirement would be the most definitive method of confirming a true reaction. Therefore, patients with mild systemic reactions who did not receive epinephrine were excluded from analysis.

Several precautionary methods were employed throughout the study to optimize subcutaneous delivery of immunotherapy extract. Before starting SCIT or during SCIT, most patients (26/28) underwent an ultrasonographic assessment of the posterolateral arm to determine the subcutaneous soft tissue depth to decrease the probability of an intramuscular delivery. Furthermore, extract was injected at a 45-degree angle with cautious needle advancement to increase the probability of subcutaneous extract delivery. These approaches to injections may have contributed to a lower observed risk of reaction per injection.

The risk factors for systemic reactions are well documented [2] and our study supports these findings. In our study, 39.3% of the patients requiring epinephrine had asthma, although injections are generally withheld when patients have symptoms of uncontrolled asthma. The presence of asthma alone as an independent risk factor further reinforces the hypothesis that patients with asthma are at a higher risk for systemic reactions, and SCIT should be administered with great caution.

Five (17.9%) of the patients requiring epinephrine reacted to the first injection from a newly reordered extract. Furthermore, 2 of the 3 patients who experienced grade 4 reactions had also received their dose from a newly reordered extract. These observations support the hypothesis that the significant differences in concentration between that of an expiring extract and a newly reordered extract are sufficient to evoke severe systemic reactions. Therefore, the dose for the first injection from a new reordered extract should be reduced to 50% or less than the previous maintenance dose to reduce the probability of evoking a systemic reaction.

Within our data, we observed more reactions during the winter season (35.7%) than any other season. Although reactions occurred year-round, the increased frequency of reactions during the winter may in turn reflect the increased volume of immunotherapy initiations during the autumn season. Consequently, these new initiations would then be receiving injections from vial number 4 during the winter season, which was associated with the highest risk of systemic reaction.

Amongst the most severe reactions, we observed that these patients were between the ages of 16 to 53 years. All three patients were being treated for multiple allergies, and the reaction onset was within 30 min of the injection. Multiple risk factors for an increased probability of reaction and reaction severity were identified, with asthma in the past history of a majority of these patients, and a majority of these reactions occurring during winter. Furthermore, a majority of patients were receiving the first injection from a newly reordered vial. These patients all required multiple doses of intramuscular epinephrine and were transferred to the hospital for further management and observation.

There are some limitations to this retrospective study. Although a prospective study would provide more consistent data and be powered for generalizability of predictive factors, we do not believe that a prospective study would change the likelihood of epinephrine administration. This study was also limited to patients on SCIT for aeroallergens and did not consider the incidence or risk factors for patients on venom immunotherapy, limiting the generalizability of these findings to other SCIT populations. Furthermore, the narrow geographic and demographic patient profile from this single-center study may limit the generalizability of our results. Similar studies in larger multicenter settings are needed to confirm these observations.

Conclusion

Our findings complement the available data on systemic reactions with subcutaneous immunotherapy and provide further information about the rate and nature of reactions requiring epinephrine [19]. The recommendations in the CSACI Immunotherapy Manual provide an approach to standardizing prescriptions for SCIT to maximize immunotherapy efficacy and reduce the risk of systemic reactions. Taken together, these observations provide important objective information to clinicians about the potential risks for systemic reactions in patients considering SCIT.

Availability of data and materials

The datasets used and analyzed during the current study are available from the corresponding author upon reasonable request.

Abbreviations

SCIT:

Subcutaneous immunotherapy

CSACI:

Canadian Society of Allergy and Clinical Immunology

WAO:

World Allergy Organization

Ml:

Milliliter

MmHg:

Millimeter of mercury

IM:

Intramuscular

References

  1. Cox L, Nelson H, Lockey R, et al. Allergen immunotherapy: a practice parameter third update. J Allergy Clin Immunol. 2011;127:S1–55.

    Article  PubMed  Google Scholar 

  2. Cox L. Allergen immunotherapy: immunomodulatory treatment for allergic diseases. Expert Rev Clin Immunol. 2006;2(4):533–46.

    Article  CAS  PubMed  Google Scholar 

  3. Reid MJ, Lockey RF, Turkeltaub PC, Platts-Mills TA. Survey of fatalities from skin testing and immunotherapy 1985–1989. J Allergy Clin Immunol. 1993;92:6–15.

    Article  CAS  PubMed  Google Scholar 

  4. Lockey RF, Benedict LM, Turkeltaub PC, Bukantz SC. Fatalities from immunotherapy (IT) and skin testing (ST). J Allergy Clin Immunol. 1987;79:660–77.

    Article  CAS  PubMed  Google Scholar 

  5. Bernstein DI, Wanner M, Borish L, Liss GM. Twelve-year survey of fatal reactions to allergen injections and skin testing: 1990–2001. J Allergy Clin Immunol. 2004;113:1129–36.

    Article  PubMed  Google Scholar 

  6. Cox L, Larenas-Linnemann D, Lockey RF, Passalacqua G. Speaking the same language: the World Allergy Organization Subcutaneous Immunotherapy Systemic Reaction Grading System. J Allergy Clin Immunol. 2010;125:569e574.

  7. Lim CE, Sison CP, Ponda P. Comparison of pediatric and adult systemic reactions to subcutaneous immunotherapy. J Allergy Clin Immunol Pract. 2017;5:1241–7.

    Article  PubMed  Google Scholar 

  8. Holland CL, Samuels KM, Baldwin JL, Greenhawt MJ. Systemic reactions to inhalant immunotherapy using 1:1 target dosing. Ann Allergy Asthma Immunol. 2014;112:453–8.

    Article  PubMed  Google Scholar 

  9. DaVeiga SP, Liu X, Caruso K, Golubski S, Xu M, Lang DM. Systemic reactions associated with subcutaneous allergen immunotherapy: timing and risk assessment. Ann Allergy Asthma Immunol. 2011;106(533–537):e2.

    Google Scholar 

  10. Nacaroglu HT, Erdem SB, Sumer O, et al. Local and systemic reactions to subcutaneous allergen immunotherapy: ten years’ experience in a pediatric clinic. Ann Allergy Asthma Immunol. 2016;116:349–53.

    Article  CAS  PubMed  Google Scholar 

  11. Kartal O, Gulec M, Caliskaner Z, Musabak U, Sener O. Safety of subcutaneous immunotherapy with inhalant allergen extracts: a single-center 30-year experience from Turkey. Immunopharmacol Immunotoxicol. 2015;37(3):280–6.

    Article  CAS  PubMed  Google Scholar 

  12. Rottem M, Egbarya A. Subcutaneous Immunotherapy in Northern Israel: efficacy and Safety. Isr Med Assoc J. 2014;16(9):539–43.

    PubMed  Google Scholar 

  13. Santos N, Pereira AM, Silva R, Torres da Costa J, Plácido JL. Characterisation of systemic reactions to subcutaneous immunotherapy with airborne allergens and classification according to WAO 2010. Allergol Immunopathol. 2015. 43(1):25-31.

  14. Ragusa FV, Passalacqua G, Gambardella R, et al. Nonfatal systemic reactions to subcutaneous immunotherapy: a 10-year experience. J Investig Allergol Clin Immunol. 1997;7(3):151–4.

    CAS  PubMed  Google Scholar 

  15. Ragusa VF, Massolo A. Non-fatal systemic reactions to subcutaneous immunotherapy: a 20-year experience comparison of two 10-year periods. Eur Ann Allergy Clin Immunol. 2004;36(2):52–5.

    PubMed  Google Scholar 

  16. Moreno C, Cuesta-Herranz J, Fernandez-Tavora L, Alvarez-Cuesta E. Immunotherapy safety: a prospective multi-centric monitoring study of biologically standardized therapeutic vaccines for allergic diseases. Clin Exp Allergy. 2004;34:527–31.

    Article  CAS  PubMed  Google Scholar 

  17. Kim H, Moote DW, Waserman S. Immunotherapy Manual. Canadian Society of Allergy and Clinical Immunology, 2010.

  18. Phillips JF, Lockey RF, Fox RW, Ledford DK, Glaum MC. Systemic reactions to subcutaneous allergen immunotherapy and the response to epinephrine. Allergy Asthma Proc. 2011;32(4):288–94.

    Article  CAS  PubMed  Google Scholar 

  19. Allergen immunotherapy: a practice parameter second update. J Allergy Clin Immunol. 2007. 120:S25eS85.

Download references

Acknowledgements

Not applicable.

Funding

None.

Author information

Authors and Affiliations

Authors

Contributions

NM, US and HK helped develop the concept of the paper. US collected patient data. NM and HK analyzed and interpreted the patient data regarding the characteristics and incidence of systemic reactions. KR and NM authored the body of the manuscript. KR, SJ and HK have revised and edited the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Kara Robertson.

Ethics declarations

Ethics approval and consent to participate

Research ethics approval was obtained through McMaster University in Hamilton, Ontario, Canada (Project number: 4213-C).

Consent for publication

Not applicable.

Competing interests

SJ has been on speakers’ bureaus for Aralez, Astra Zeneca, Sanofi, and Novartis, has received research support from Takeda, and is on the national advisory board for Sanofi. HK has been on the speakers’ bureaus and advisory boards for AstraZeneca, Aralez, Boehringer Ingelheim, CSL Behring, Kaleo, Merck, Novartis, Pediapharm, Sanofi, Shire and Teva, and has received research funding from Sanofi and Novartis as well as research support from AstraZeneca and Shire.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Robertson, K., Montazeri, N., Shelke, U. et al. A single centre retrospective study of systemic reactions to subcutaneous immunotherapy. Allergy Asthma Clin Immunol 16, 93 (2020). https://doi.org/10.1186/s13223-020-00491-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13223-020-00491-5

Keywords